LIMIT Switch does not stop movement

Discussion in 'General Talk' started by Roman Burtyk, Jul 1, 2022.

  1. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    Just finished my 1010 build, verified all connections are correct. Drove gantry to limit switch and it crushed it.

    None of the switches limit movement. LED lights up.

    What is the issue?
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,878
    Likes Received:
    4,285
    1) Did you test the switches (safely, by hand) in the Troubleshooting tab first? Making sure they all work and also that the correct axis lights up (to make sure no accidental X into Z, etc mistakes made its way in)
    2) Did you enable Hard Limits in Grbl Settings?
     
  3. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    RE #1, copy, all verified.

    RE#2 no, how do i do that?
     
  4. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,002
    Likes Received:
    1,676
  5. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    wow, who knew, i will give it a try. Will let you know too. Thanks so much!!
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,878
    Likes Received:
    4,285
    Next to the machine selection, flip the Limit Switches Installed switch to the ON position (it enables Homing and Hard Limits for you in the section below). Save and Reset when Prompted
     
  7. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    went into tools menu, set hard limit to on.... it works thanks. Crushed a switch in this little exercise. Good thing Openbuilds sells more.
     
    Peter Van Der Walt likes this.
  8. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    limits working now but the Blk Box is not responding properly. I boot wth current faults despite no jogging. I have adjusted current countless times to no avail.

    I have verified via continuity test all connections are correct. Bottom line is Blk Box is non functional... requesting RMA
     
  9. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,878
    Likes Received:
    4,285
    Please contact support.openbuilds.com > new ticket for assistance thanks
     
  10. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    contacted openbuilds support for return, thanks Peter-
     
  11. Roman Burtyk

    Builder

    Joined:
    Jun 17, 2022
    Messages:
    7
    Likes Received:
    1
    Peter, as the sage of Openbuilds, please tell me what the default settings should be for the cnc 1010.

    in an effort to t-shoot, I loosened the flex collar from the threaded rod to observe motor response. Turned sys on, motors either no responsive or I get random array of over current faults. Bummed.
     
  12. sharmstr

    sharmstr OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 23, 2018
    Messages:
    2,059
    Likes Received:
    1,448
    Go into the grbl settings tab and select the Lead 1010 profile. Save.

    But sounds like you need a replacement.
     