Welcome to Our Community

Some features disabled for guests. Register Today.

XYZ Probe Plus

Discussion in 'General Talk' started by GARY GEORGE, Dec 16, 2020.

  1. GARY GEORGE

    Builder

    Joined:
    Oct 2, 2020
    Messages:
    9
    Likes Received:
    2
    Hi Folks,
    Received my new openbuilds XYZ Probe and connected ok. First probe worked fine and all good. However any subsequent probe the probe moves to the center of the probe but the Z travel wants to go past the top of the probe plate. I have to quickly abort. What am I doing wrong?
     
  2. sharmstr

    sharmstr OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 23, 2018
    Messages:
    2,059
    Likes Received:
    1,448
    Make sure your connection is good before running the probe job. Common problem is not having the magnet on the flat of the collet nut. Attach the magnet, lift the plate up to the bit and verify that the green lights are lit on the probe plate.
     
    #2 sharmstr, Dec 16, 2020
    Last edited: Dec 16, 2020
    Peter Van Der Walt likes this.
  3. GARY GEORGE

    Builder

    Joined:
    Oct 2, 2020
    Messages:
    9
    Likes Received:
    2
    Thanks Shawn for the prompt response. Much appreciated.
     
  4. GARY GEORGE

    Builder

    Joined:
    Oct 2, 2020
    Messages:
    9
    Likes Received:
    2
    Thanks Shawn. Problem solved by cleaning the collet nut.
     
    sharmstr likes this.
  5. Jacob Christiansen

    Builder

    Joined:
    Mar 13, 2021
    Messages:
    9
    Likes Received:
    7
    I'm having a similar issue. The green LEDs light up, but the z travel doesn't stop and i have to abort every time... Any suggestions?
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,868
    Likes Received:
    4,283
    Good clean electical connections throughout. Clean collet nut, clean endmill, some endmills have coatings, where you placed the magnet, etc. Signal wire terminals checked , etc.

    Do not test by probing, use the Troubleshooting tab - much safer
     
  7. Jacob Christiansen

    Builder

    Joined:
    Mar 13, 2021
    Messages:
    9
    Likes Received:
    7
    after posting I went through many of those. I verified all electrical connections between the Black Box and the XYZ probe plus. the collet nut is clean, and the endmill is a brand new sharkbit (i have tried 3 different bits now). I have tried placing the magnet on the endmill shank, and on the collet nut.
    The part that confuses me most is that the green LEDs come on, but that seems to be it. I did notice that there appears to be 6 LEDs but only 5 light up. I don't know if that is an indication of anything...
    I will refer to the troubleshooting again and see if I missed something.
     
  8. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,868
    Likes Received:
    4,283
    Even though the lights come on (just shows you have power) doesn't mean the signal makes its way back to the controller (wiring there could be loose or wrong). The Troubleshooting tab in CONTROL shows whether the signal got to Grbl. Here you can test touching magnet to plate, bridging SIG to GND, etc to determine where the issue is.
     
    sharmstr likes this.
  9. Jacob Christiansen

    Builder

    Joined:
    Mar 13, 2021
    Messages:
    9
    Likes Received:
    7
    Peter,
    Thank you for your help so far.

    I used my multimeter last night and checked continuity, and resistance between both ends of the wires with the plug installed. GND, PWR, and SIG all have good continuity from plug to plug, and the resistance seems normal for 22AWG wire across all 3 as well.
    As stated before, the lights come on when the magnet is placed directly on the plate, as well as when it is placed on the bit and then the plate is touched to the bit.
    There is a "probe" light on the side of the black box that turns on when contact is made either directly, or through the bit.
    In the control software on the troubleshooting tab the status of the probe indication never changes with contact of any kind.
    I have checked multiple times to make sure that everything is plugged in well, and I seperated the wire for the probe from everything else.
    I plan to get a pack of ferrite chokes, but those will take a few days to get here...
    Any other suggestions in the meantime?
     
  10. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,868
    Likes Received:
    4,283
    That indicates more of a problem maybe with the BlackBox.

    Wire two wires to SIG and GND (NB careful, nothing to V+) and touch them together while watching troubleshooting tab. Ie eliminate probe, test just the Port on the BlackBox
    If it doesn't change, speak to http://support.openbuilds.com/support/home and they will sort you out
     
  11. Jacob Christiansen

    Builder

    Joined:
    Mar 13, 2021
    Messages:
    9
    Likes Received:
    7
    Thank You! I will give that a try when I get home from work this afternoon.
    I really appreciate your help on this!
     
    Peter Van Der Walt likes this.
  12. Tyler Skelton

    Builder

    Joined:
    Feb 16, 2023
    Messages:
    9
    Likes Received:
    2
    Were you ever able to resolve this issue? i'm experiencing the same issue...
     
  13. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,002
    Likes Received:
    1,676
    If you are having the same exact issue, then do the same test as decribed above to see where the issue may be and follow those instructions:
    Submit a ticket
     
  14. Tyler Skelton

    Builder

    Joined:
    Feb 16, 2023
    Messages:
    9
    Likes Received:
    2
     
  15. Tyler Skelton

    Builder

    Joined:
    Feb 16, 2023
    Messages:
    9
    Likes Received:
    2
    I have performed all the tests mentioned above with no resolution. My wires are fine, get green lights on probe and blackbox, as well as a triggered indication in the troubleshooting.
    while trying to perform XYZ probe I encounter one of the following issues:
    -its either not responding/performing probe task at all (i clear alarm and receive Error-1) followed by "probe complete" window
    -responds but needs to be aborted because it wants to press down further than the touch plate on z axis probe
    -performs (z axis) but stops and does not continue to x/y probing
     
  16. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,868
    Likes Received:
    4,283
    Sounds to me like you skipped over step 7.1 (7.2 relates) and possibly also step 4.2 of the BlackBox X32 Documentation when you were working through the docs during initial setup. Check out the mentioned sections and ensure you follow the documentation.
     
  17. Tyler Skelton

    Builder

    Joined:
    Feb 16, 2023
    Messages:
    9
    Likes Received:
    2
    Thank you for replying! You were indeed correct! Firmware needed to be flashed
    and updated. Much appreciated!
     
    Peter Van Der Walt likes this.
  18. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,868
    Likes Received:
    4,283
    Sweet, do check 4.2 as well, in case you skipped it earlier :thumbsup:
     

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice