Keep us in the loop @Semper Why , I'm more than happy to help with the info I have in my head but my machine is in storage for the foreseeable so...
I had so much interference with mine since I installed a spindle that I've actually disabled them - Not a bad idea to have training wheels but I'm...
$21 will enable your hard limits, $22 will enable homing for those switches, and $23 will define in which direction the axes move to find HOME....
This lends itself well to Software, send $$ to your xPro and let us know what the values are :thumbsup:
I’d get in touch and see about getting a revised manual? Although I highly doubt it’s been changed since its inception.
:confused: I scoured the digital manual you posted on the 25th Sept and found no mention of a jumper, are you sure the manuals are the same bud?
With this jumper, you're basically telling the VFD that either "you're controlling it using the buttons/pot on the front", or "expect a PWM signal...
That's what, 4.1% (ish) of the maximum (1748) RPM value. What's do you have PD007, PD011, PD072 & PD073 set to? Also, what are your $$ GRBL...
How have you got it all connected? (xPro & VFD)?
That's a great read, everything I've found to be an issue with mine is in there in one way or another, I wish I'd have read this before. Thanks...
Yep, we're good. @Semper Why , here are the confirmed working PD values to go with a confirmed working wiring diagram for the xPro v4 and the...
No rush mate, it's appreciated. I've just this second had success moving the machine without it throwing-down - There was no ground to the pin on...
Hey @Semper Why , this is exactly what's happening for me, too (Hard Limit Error). I will keep pressing on with mine as I want it fixed so check...
@Peter Van Der Walt , thank you for the pointers! - I used 4 Core CY Cable and connected the shield to ground (earth) on the VFD, but not to pin...
Just a bit more on this; I set the VFD to use the operator and the pot on the front and when the machine is moving, and I turn the spindle on...
I factory reset my VFD and set it as per this table (note the additional settings PD072, PD011) [IMG] Now I think I'm getting somewhere because...
Also, @JacobE1988 , if you could let me know what you're PD values are, that would be really helpful. I've gone with these for now, but I'm still...
I'll set mine up from a factory reset when I get home tonight, note down PD changes and see how it goes. The theory is there :)
First of all, how have you got on over the last few weeks, did you manage to get your xPro v4 to talk to your VFD, or are you still running it...
Did not know that, I shall cool mine from now then!