Separate names with a comma.
Some features disabled for guests. Register Today.
See docs:blackbox:faq-emi [OpenBuilds Documentation]
...error 15- jog exceeds machine travel. Command ignored, and also error 9 g code locked out during alarm or jog state. Im assuming that the...
Error 9 is a general error, usually something else has gone wrong before hand. In your case it's this: If you're confident that your probe setup...
...well? Where do I find a list of G-code error messages. I got a error 9 a couple times, I think it is "you hit the limit switch dummy" Where...
...and serial log leading up to your error, thus may be inaccurate. (Error 9 for example, is a Symptom of an Earlier ALARM (the error code thus...
Thank you again for still working on this! Curious, if you launch from a console do you get any errors? The last few updates (by the firmware.bin...
Hello! After copying the post processor file "openbuilds_mm.pp" into the postprocessing Aspire folder named PostP (I'm using Aspire version 9 on...
Ok guys. It was my fault... I didn't set 0 point before start the job. It works fine! Hello world job done! Thanks!
...the center of the probe plate and the stopped and threw an error: Error 9-gcode locked out during alarm or jog state. This was accompanied with...
...first z axis hits z limit and error 1 flashes a second and then error 9 in the screen. My seller send me different motors and I had to reverse...
...probe is, I getting error when I initiate the auto probing giving error 9-G code locked out during alarm or jog state [G4 P0.3] Saying This...
...stops mid job do you get an error message? What does it say (not just "Error 9" - there will be another error message immediately before that....
I already use this machine candle and it works quite well and it's grbl and I draw with aspire 9 with openbuilds for example it doesn't give me...
Test switches on the Troubleshooting tab, not working or wired to wrong axis port perhaps?
...at almost the same exact spot as last time. This time I got a GRBL error 9. G-code locked otu druing alarm or jog state x153.15417 y-3.16876...
I factory reset my VFD and set it as per this table (note the additional settings PD072, PD011) [IMG] Now I think I'm getting somewhere because...
What controller do you have? Please post your grbl settings here. Alex.
Here's what the console on Candle says:
You queue up in one send. G0 X10\nM8
...not be Soft Limits then, so do grab a screenshot so we can see why it errors out. Error 9 is just the symptom, which alarm locked it is the...