Y limit light on

Discussion in 'Controller Boards' started by PaulN, Dec 28, 2019.

  1. PaulN

    PaulN New
    Builder

    Joined:
    May 23, 2019
    Messages:
    13
    Likes Received:
    4
    Hello

    just starting my workbee 1010 everything looks good however the status light on Y limit is on(red), when all others are off (green)

    "home all " Z and X homed but stopped there

    Any help on troubleshooting is appreciated

    Paul
     
  2. Christian James

    Christian James Journeyman
    Builder

    Joined:
    Jun 8, 2018
    Messages:
    434
    Likes Received:
    210
    I would start by unplugging the switch wires from the controller, then stick a (ohms) meter across the terminals of the switch and see what you get when its actuated. If its OK, then check at the ends of the wires (connector) while its still disconnected.. You must eliminate that before looking at the controller or something else
     
  3. PaulN

    PaulN New
    Builder

    Joined:
    May 23, 2019
    Messages:
    13
    Likes Received:
    4
    I will try that tomorrow, it acts like a nc contact.

    Suspect a bad switch

    Thanks for your input
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    13,753
    Likes Received:
    4,070
    If you have a bad part, http://support.openbuilds.com/support/home will sort you out :)

    That said, its probably more likely wiring, switches aren't very likely to have issues out of the box (can fail after several thousand actuations but thats a couple years down the line)
     
  5. PaulN

    PaulN New
    Builder

    Joined:
    May 23, 2019
    Messages:
    13
    Likes Received:
    4
    Peter,

    thanks for the info, I'll be working on the build today and looking at the switch and wiring is on my list!

    I agree support has been very good in helping.

    I ran the motors briefly on Saturday seem to growl a lot not sure if this is normal.
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    13,753
    Likes Received:
    4,070
    There is a sine-wave running through the coils, so a gentle hum is normal, growl, sounds like a tiger on the loose :)
    Make a recording of the noise and I'll be happy to have a listen and tell you if its normal though
     
  7. PaulN

    PaulN New
    Builder

    Joined:
    May 23, 2019
    Messages:
    13
    Likes Received:
    4
    okay
    Checked wire harness no issues
    Checked switch open and closed no change
    Removed x limit and put in place of y limit status light went to off, when activated got hard limit triggered
     
  8. PaulN

    PaulN New
    Builder

    Joined:
    May 23, 2019
    Messages:
    13
    Likes Received:
    4
    everything came up nice this morning no growl hope to cut later today
     