Having a little trouble getting green lights on my controllers

Discussion in 'CNC Mills/Routers' started by McFuddlebutt, Mar 14, 2019.

  1. McFuddlebutt

    Builder

    Joined:
    Oct 9, 2017
    Messages:
    18
    Likes Received:
    2
    I'm getting my Large Sphinx build buttoned up and I'm having a bit of trouble getting green lights on all my controllers. As it stands, I get 1 green light on the X axis but 3 reds on the rest. I've attached my schematic that I drew up before I put everything together. I'm wondering if it's a bad solder joint or perhaps a bad crimp onto the DuPont connectors? I'm also curious as to if my dip-switch settings are correct. I know it's a bit of a mess right now but I have to make sure I've got everything correctly wired before I finish the wire cleanup.


    Note that I didn't include the limit switches in the drawing, those are pretty self explanatory. They are the 6 pin connector in between the two Y axis plugs.

    Any help is appreciated!

    [​IMG]


    [​IMG]


    [​IMG]

    [​IMG]

    [​IMG]

    [​IMG]
    This photo was taken when I had the wire colors reversed. I've switched it around to match the drawing.
    [​IMG]
     
    #1 McFuddlebutt, Mar 14, 2019
    Last edited: Mar 14, 2019
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    13,749
    Likes Received:
    4,070
    Unplug the Enable plug from the drivers: By default its "enabled" so unplugging the connector is a quick check if it enables. (When enabled the light is green)

    If it does then the Enable signal off the controller isnt working correctly (Inverted? or Wiring?)
     
  3. McFuddlebutt

    Builder

    Joined:
    Oct 9, 2017
    Messages:
    18
    Likes Received:
    2

    Gave that a go, but no joy. Does my wiring schematic look correct? How about the dip switches? I did notice the first controller in the line that has +5v got considerably warm to the touch when I had the machine on for a bit. I hope I didn't damage anything with bad wiring. I'm checking continuity on my crimps as we speak.

    Thank you for the help!
     
  4. McFuddlebutt

    Builder

    Joined:
    Oct 9, 2017
    Messages:
    18
    Likes Received:
    2
    I think I see where I might have goofed up. See, I had originally run out of green wire so I had to switch it to another color, when I ran out of that other color I just went and bought all new green wire and re crimped it. I might have been working on plans that used an old wire color. What I'm seeing on my board is that I crimped a dupont plug that went GRND,ST,DIR,EN but I wired it into the controller as GRND,DIR,ST,EN

    Let me switch it and see if that gives me some green lights.


    *EDIT

    Made the switch but it's still no go. I checked continuity with everything and it all checks out. Would the fact that the +5v is only getting +4.7v do anything?

    Also, The first controller that is connected to the +5v on the board gets REALLY hot now. What would cause that?
     
    #4 McFuddlebutt, Mar 15, 2019