    Hello!

    I am trying to jog my cnc using interface, it won't move to the right on x axis but will move to the left. Same with going up and down on y axis. Does a similar thing on z axis. I have limit switches setup and can trigger them using CONTROL. In CONTROL, I get full range of movement.

    Also something is weird with the Z on the interface. Sometimes I hit up on the Z and it'll go down. I never run into that issue while using CONTROL on my laptop.

    Any inputs? Will submit videos below from my phone.

    Thanks!
     
  2. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    This is how it moves in control
     

    Attached Files:

  3. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    This is movement in interface
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,832
    Likes Received:
    4,275
    No file attached
     
  5. David the swarfer

    David the swarfer OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Aug 6, 2013
    Messages:
    3,427
    Likes Received:
    1,906
    have you calibrated the Interfaces buttons?
    do all the anti EMI stuff in the documentation? EMI can afffect the touch sensitive buttons on the Interface.
     
  6. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    Checked everything. I don’t have shielded cabling though, but I read that was worst case scenario.
     
  7. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
     

    Attached Files:

  8. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    How do you calibrate the interface button?

    If you mean calibrating esteps, yes I have done that. The movements are basically exact currently.

    Still having the movement issue in interface. I have no other wires running near/along the wire that goes from the interface into the the x32.
     
  9. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    Getting this error from interface only after fully homing the cnc. Control doesn’t get this error. How do I resolve this?
     

    Attached Files:

  10. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,832
    Likes Received:
    4,275
    Is your Interface Firmware up to date? (V1.57 at this time)

    CONTROL and Interface both use the same backend logic. The error states that a) you have soft limits enabled and b) something in your direction/homing setup isn't quite right. Travel distances, homing dir, axis dir, etc.

    We don't recommend using Soft Limits to people not yet familiar with multi coordinate systems, disable it for now. Easier option is to install min and max switches if you really wish to be safer. See 2nd half of docs:blackbox-x32:connect-xtension-limit [OpenBuilds Documentation]

    In essence Soft Limits needs multiple aspects of Homing to be set up 100% technically correct, you can get into that later... It takes a while to grasp machine coordinates. See Frequently Asked Questions

    The issues in your video relates to the values of Max travel in Grbl Settings, but you can also sidestep that until you have a better understanding of coordinate systems, by following the recommendation to turn off soft limits.
     
    David the swarfer likes this.
  11. David the swarfer

    David the swarfer OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Aug 6, 2013
    Messages:
    3,427
    Likes Received:
    1,906
    I believe this what you need to do
    docs:interface:device-test-mode [OpenBuilds Documentation]
     
  12. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,832
    Likes Received:
    4,275
    Per the video his buttons works fine. Soft limit calculation stops the move per max travel. Disabling soft limits eases learning curve, no need to immediately understand MCS
     
  13. sackindustries

    Builder

    Joined:
    Feb 22, 2023
    Messages:
    21
    Likes Received:
    2
    Ahh. Yeah, I had soft limits enabled. For some reason, CONTROL didn't let me save the profile if I didn't have it on when I was doing the setup initially after importing a profile. I disabled it through interface and the movement issues are all fixed.
     