Welcome to Our Community

Some features disabled for guests. Register Today.

G Code Error

Discussion in 'CAM' started by Fintan Mitchell, Jul 16, 2022.

  1. Fintan Mitchell

    Builder

    Joined:
    Jul 3, 2022
    Messages:
    9
    Likes Received:
    0
    Hello,

    I'm getting the following error when the program begins to run. Does anyone have any ideas why this is happening?

    Thanks,
    Fintan
     

    Attached Files:

  2. Alex Chambers

    Alex Chambers Master
    Moderator Builder

    Joined:
    Nov 1, 2018
    Messages:
    2,681
    Likes Received:
    1,321
    It's telling you that a limit switch has been triggered - ie; not a g-code error but a problem with the machine. If there's no obvious cause then there could be an electrical issue - do you have a vfd and spindle? If so is any of its wiring any where near other wiring (in the drag chain with the limit switch wiring for example)?
    Alex.
     
  3. Fintan Mitchell

    Builder

    Joined:
    Jul 3, 2022
    Messages:
    9
    Likes Received:
    0
    It's a spindle but it's not a vfd. All the wires look to be in working order. I used the check size after I set zero but that also wouldn't return to set zero.
     
  4. sharmstr

    sharmstr OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 23, 2018
    Messages:
    2,030
    Likes Received:
    1,428
    As Alex said. But I'll add that you can go into the troubleshooting tab and see the status of your limit switches to help diagnose the problem.
     
    Alex Chambers likes this.
  5. Alex Chambers

    Alex Chambers Master
    Moderator Builder

    Joined:
    Nov 1, 2018
    Messages:
    2,681
    Likes Received:
    1,321
    Couldn't quite see the background of your pics on my phone - if you are using Openbuilds Control then you can use the troubleshooting tab to check that the limit switches are working correctly.
    It isn't just vfd cables that can cause problems (although they are the worst for interference - emi) if your spindle is mains powered and that cable is lying next to your limit switch wiring that could also create a "false trigger".
    What are you using as limit switches? Are they "normally open" or "normally closed"?
    Alex.
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    13,753
    Likes Received:
    4,070
  7. Fintan Mitchell

    Builder

    Joined:
    Jul 3, 2022
    Messages:
    9
    Likes Received:
    0
    I'm not seeing anything useful regarding the limit switches in the troubleshoot tab and they're normally open.
    Cheers for your help.
     
  8. Fintan Mitchell

    Builder

    Joined:
    Jul 3, 2022
    Messages:
    9
    Likes Received:
    0
    I dont have my dust collection set up so it could be that
     
  9. Fintan Mitchell

    Builder

    Joined:
    Jul 3, 2022
    Messages:
    9
    Likes Received:
    0
    I'm getting this output in the Serial Console:

    This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.

    [17:50:41] [ X200.368 Y-183.863 Z57.484 F333 ] ok

    [17:50:41] [ X200.825 Y-183.938 Z57.468 ] ok

    [17:50:41] [ X201.287 Y-183.945 Z57.451 ] ok

    [17:50:41] [ X201.746 Y-183.884 Z57.435 ] ok

    [17:50:41] [ X202.19 Y-183.755 Z57.419 ] ok

    [17:50:42] [ X202.61 Y-183.561 Z57.403 ] ok

    [17:50:42] [ X202.997 Y-183.308 Z57.387 ] ok

    [17:50:42] [ X203.342 Y-183 Z57.371 ] ok

    [17:50:42] [ X203.638 Y-182.644 Z57.354 ] ok

    [17:50:42] [ X203.877 Y-182.248 Z57.338 ] ok

    [17:50:42] [ X204.056 Y-181.821 Z57.322 ] ok

    [17:50:42] [ X204.169 Y-181.373 Z57.306 ] ok

    [17:50:42] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:50:42] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:50:42] [ X204.214 Y-180.912 Z57.29 ] ALARM:1

    [17:50:43] [ X204.214 Y-180.912 Z57.29 ] [MSG:Reset to continue]

    [17:50:43] [ X204.214 Y-180.912 Z57.29 ] ok

    [17:50:43] [ X204.191 Y-180.451 Z57.274 ] Grbl 1.1g ['$' for help]

    [17:50:43] [ X204.191 Y-180.451 Z57.274 ] [MSG:Check Limits]

    [17:50:43] [ X204.191 Y-180.451 Z57.274 ] [MSG:'$H'|'$X' to unlock]

    [17:50:43] [ ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]<hr>This error may just be a symptom of an earlier event:<br> ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.

    [17:50:43] [ ERROR ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]

    This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.
    [17:50:43] [ X204.191 Y-180.451 Z57.274 ] error:9

    [17:50:46] [ ] Grbl 1.1g ['$' for help]

    [17:50:46] [ ] [MSG:Check Limits]

    [17:50:46] [ ] [MSG:'$H'|'$X' to unlock]

    [17:50:47] [ ] [MSG:Caution: Unlocked]

    [17:50:47] [ JOB COMPLETE ] Job completed in 00h00m

    [17:50:47] [ ] ok

    [17:50:49] [ $J=G91G21Z-1F2500 ] ok

    [17:50:49] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:50:49] [ $G ] ok

    [17:50:49] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:50:49] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:50:49] [ ] ALARM:1

    [17:50:49] [ ] [MSG:Reset to continue]

    [17:50:49] [ ] Grbl 1.1g ['$' for help]

    [17:50:49] [ ] [MSG:'$H'|'$X' to unlock]

    [17:50:51] [ ] Grbl 1.1g ['$' for help]

    [17:50:51] [ ] [MSG:'$H'|'$X' to unlock]

    [17:50:51] [ ] [MSG:Caution: Unlocked]

    [17:50:51] [ ] ok

    [17:50:55] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:50:55] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:50:55] [ ] ALARM:1

    [17:50:56] [ ] [MSG:Reset to continue]

    [17:50:56] [ ] Grbl 1.1g ['$' for help]

    [17:50:56] [ ] [MSG:'$H'|'$X' to unlock]

    [17:50:58] [ ] Grbl 1.1g ['$' for help]

    [17:50:58] [ ] [MSG:'$H'|'$X' to unlock]

    [17:50:59] [ ] [MSG:Caution: Unlocked]

    [17:50:59] [ ] ok

    [17:51:00] [ ] Grbl 1.1g ['$' for help]

    [17:51:00] [ ] ok

    [17:51:04] [ (Made in : Autodesk CAM Post Processor) ] ok

    [17:51:04] [ (G-Code optimized for Grbl 1.1 / BlackBox controller) ] ok

    [17:51:04] [ (OpenBuilds CNC : GRBL/BlackBox) ] ok

    [17:51:04] [ (Post-Processor : OpenbuildsFusion360PostGrbl.cps V1.0.30) ] ok

    [17:51:04] [ (Units = mm) ] ok

    [17:51:04] [ (Drawing name : TeleBody v14) ] ok

    [17:51:04] [ (Program Name : Tele) ] ok

    [17:51:04] [ (5 Operations :) ] ok

    [17:51:04] [ (1 : Pickups) ] ok

    [17:51:04] [ ( Work Coordinate System : G54) ] ok

    [17:51:04] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:04] [ $G ] ok

    [17:51:04] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:04] [ ( Spindle : RPM = 5000) ] ok

    [17:51:04] [ ( Machining time : 11 min 25 sec) ] ok

    [17:51:04] [ (2 : Pickups Finish) ] ok

    [17:51:04] [ ( Work Coordinate System : G54) ] ok

    [17:51:04] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:04] [ $G ] ok

    [17:51:04] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:04] [ ( Spindle : RPM = 5000) ] ok

    [17:51:04] [ ( Machining time : 3 min 20 sec) ] ok

    [17:51:04] [ (3 : ControlCavity) ] ok

    [17:51:04] [ ( Work Coordinate System : G54) ] ok

    [17:51:04] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:04] [ $G ] ok

    [17:51:04] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:04] [ ( Spindle : RPM = 5000) ] ok

    [17:51:04] [ ( Machining time : 12 min 43 sec) ] ok

    [17:51:04] [ (4 : RoughShape) ] ok

    [17:51:04] [ ( Work Coordinate System : G54) ] ok

    [17:51:04] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:04] [ $G ] ok

    [17:51:04] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:04] [ ( Spindle : RPM = 5000) ] ok

    [17:51:04] [ ( Machining time : 8 min 53 sec) ] ok

    [17:51:04] [ (5 : NeckPocket) ] ok

    [17:51:04] [ ( Work Coordinate System : G54) ] ok

    [17:51:04] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:04] [ $G ] ok

    [17:51:04] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:05] [ ( Spindle : RPM = 5000) ] ok

    [17:51:05] [ ( Machining time : 6 min 36 sec) ] ok

    [17:51:05] [ G90 G94 G17 ] ok

    [17:51:05] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:05] [ $G ] ok

    [17:51:05] [ G21 ] ok

    [17:51:05] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:05] [ $G ] ok

    [17:51:05] [ (When using Fusion 360 for Personal Use, the feedrate of) ] ok

    [17:51:05] [ (rapid moves is reduced to match the feedrate of cutting) ] ok

    [17:51:05] [ (moves, which can increase machining time. Unrestricted rapid) ] ok

    [17:51:05] [ (moves are available with a Fusion 360 Subscription.) ] ok

    [17:51:05] [ (Operation 1 of 5 : Pickups) ] ok

    [17:51:05] [ G54 ] ok

    [17:51:05] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:05] [ $G ] ok

    [17:51:05] [ (This relies on homing, see Search Results for Query: G53 fusion | OpenBuilds ) ] ok

    [17:51:05] [ G53 G0 Z-10 ] ok

    [17:51:05] [ G0 X199.928 Y-183.72 ] ok

    [17:51:05] [ S5000 M3 ] ok

    [17:51:05] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M3 M9 T0 F0 S5000]

    [17:51:05] [ $G ] ok

    [17:51:07] [ G4 P1.8 ] ok

    [17:51:07] [ G0 X199.928 Y-183.72 Z70 F5000 ] ok

    [17:51:07] [ Z60 ] ok

    [17:51:07] [ G1 Z57.5 ] ok

    [17:51:07] [ X200.368 Y-183.863 Z57.484 F333 ] ok

    [17:51:07] [ X200.825 Y-183.938 Z57.468 ] ok

    [17:51:07] [ X201.287 Y-183.945 Z57.451 ] ok

    [17:51:07] [ X201.746 Y-183.884 Z57.435 ] ok

    [17:51:07] [ X202.19 Y-183.755 Z57.419 ] ok

    [17:51:07] [ X202.61 Y-183.561 Z57.403 ] ok

    [17:51:07] [ X202.997 Y-183.308 Z57.387 ] ok

    [17:51:07] [ X203.342 Y-183 Z57.371 ] ok

    [17:51:07] [ X203.638 Y-182.644 Z57.354 ] ok

    [17:51:07] [ X203.877 Y-182.248 Z57.338 ] ok

    [17:51:07] [ X204.056 Y-181.821 Z57.322 ] ok

    [17:51:07] [ X204.169 Y-181.373 Z57.306 ] ok

    [17:51:08] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:51:08] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:51:08] [ X204.214 Y-180.912 Z57.29 ] ALARM:1

    [17:51:08] [ X204.214 Y-180.912 Z57.29 ] [MSG:Reset to continue]

    [17:51:08] [ X204.214 Y-180.912 Z57.29 ] ok

    [17:51:08] [ X204.191 Y-180.451 Z57.274 ] Grbl 1.1g ['$' for help]

    [17:51:08] [ X204.191 Y-180.451 Z57.274 ] [MSG:Check Limits]

    [17:51:08] [ X204.191 Y-180.451 Z57.274 ] [MSG:'$H'|'$X' to unlock]

    [17:51:08] [ ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]<hr>This error may just be a symptom of an earlier event:<br> ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.

    [17:51:08] [ ERROR ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]

    This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.
    [17:51:08] [ X204.191 Y-180.451 Z57.274 ] error:9

    [17:51:10] [ ] Grbl 1.1g ['$' for help]

    [17:51:10] [ ] [MSG:Check Limits]

    [17:51:10] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:11] [ ] [MSG:Caution: Unlocked]

    [17:51:11] [ JOB COMPLETE ] Job completed in 00h00m

    [17:51:11] [ ] ok

    [17:51:13] [ G53 G0 Z-5.000 ] ok

    [17:51:13] [ G0 X0 Y0 ] ok

    [17:51:13] [ G0 Z0 ] ok

    [17:51:14] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:51:14] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:51:14] [ ] ALARM:1

    [17:51:14] [ ] [MSG:Reset to continue]

    [17:51:14] [ ] Grbl 1.1g ['$' for help]

    [17:51:14] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:16] [ ] Grbl 1.1g ['$' for help]

    [17:51:16] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:16] [ ] [MSG:Caution: Unlocked]

    [17:51:16] [ ] ok

    [17:51:18] [ G53 G0 Z-5.000 ] ok

    [17:51:18] [ G0 X0 Y0 ] ok

    [17:51:18] [ G0 Z0 ] ok

    [17:51:28] [ (Made in : Autodesk CAM Post Processor) ] ok

    [17:51:28] [ (G-Code optimized for Grbl 1.1 / BlackBox controller) ] ok

    [17:51:28] [ (OpenBuilds CNC : GRBL/BlackBox) ] ok

    [17:51:28] [ (Post-Processor : OpenbuildsFusion360PostGrbl.cps V1.0.30) ] ok

    [17:51:28] [ (Units = mm) ] ok

    [17:51:28] [ (Drawing name : TeleBody v14) ] ok

    [17:51:28] [ (Program Name : Tele) ] ok

    [17:51:28] [ (5 Operations :) ] ok

    [17:51:28] [ (1 : Pickups) ] ok

    [17:51:29] [ ( Work Coordinate System : G54) ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:29] [ ( Spindle : RPM = 5000) ] ok

    [17:51:29] [ ( Machining time : 11 min 25 sec) ] ok

    [17:51:29] [ (2 : Pickups Finish) ] ok

    [17:51:29] [ ( Work Coordinate System : G54) ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:29] [ ( Spindle : RPM = 5000) ] ok

    [17:51:29] [ ( Machining time : 3 min 20 sec) ] ok

    [17:51:29] [ (3 : ControlCavity) ] ok

    [17:51:29] [ ( Work Coordinate System : G54) ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:29] [ ( Spindle : RPM = 5000) ] ok

    [17:51:29] [ ( Machining time : 12 min 43 sec) ] ok

    [17:51:29] [ (4 : RoughShape) ] ok

    [17:51:29] [ ( Work Coordinate System : G54) ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:29] [ ( Spindle : RPM = 5000) ] ok

    [17:51:29] [ ( Machining time : 8 min 53 sec) ] ok

    [17:51:29] [ (5 : NeckPocket) ] ok

    [17:51:29] [ ( Work Coordinate System : G54) ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ ( Tool 1: Flat End Mill 2 Flutes, Diam = 6.35mm, Len = 26.00mm) ] ok

    [17:51:29] [ ( Spindle : RPM = 5000) ] ok

    [17:51:29] [ ( Machining time : 6 min 36 sec) ] ok

    [17:51:29] [ G90 G94 G17 ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ G21 ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ (When using Fusion 360 for Personal Use, the feedrate of) ] ok

    [17:51:29] [ (rapid moves is reduced to match the feedrate of cutting) ] ok

    [17:51:29] [ (moves, which can increase machining time. Unrestricted rapid) ] ok

    [17:51:29] [ (moves are available with a Fusion 360 Subscription.) ] ok

    [17:51:29] [ (Operation 1 of 5 : Pickups) ] ok

    [17:51:29] [ G54 ] ok

    [17:51:29] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M5 M9 T0 F0 S0]

    [17:51:29] [ $G ] ok

    [17:51:29] [ (This relies on homing, see Search Results for Query: G53 fusion | OpenBuilds ) ] ok

    [17:51:29] [ G53 G0 Z-10 ] ok

    [17:51:29] [ G0 X199.928 Y-183.72 ] ok

    [17:51:35] [ S5000 M3 ] ok

    [17:51:35] [ $G ] [GC:G0 G54 G17 G21 G90 G94 M3 M9 T0 F0 S5000]

    [17:51:35] [ $G ] ok

    [17:51:36] [ G4 P1.8 ] ok

    [17:51:36] [ G0 X199.928 Y-183.72 Z70 F5000 ] ok

    [17:51:36] [ Z60 ] ok

    [17:51:36] [ G1 Z57.5 ] ok

    [17:51:36] [ X200.368 Y-183.863 Z57.484 F333 ] ok

    [17:51:36] [ X200.825 Y-183.938 Z57.468 ] ok

    [17:51:36] [ X201.287 Y-183.945 Z57.451 ] ok

    [17:51:36] [ X201.746 Y-183.884 Z57.435 ] ok

    [17:51:37] [ X202.19 Y-183.755 Z57.419 ] ok

    [17:51:37] [ X202.61 Y-183.561 Z57.403 ] ok

    [17:51:37] [ X202.997 Y-183.308 Z57.387 ] ok

    [17:51:37] [ X203.342 Y-183 Z57.371 ] ok

    [17:51:37] [ X203.638 Y-182.644 Z57.354 ] ok

    [17:51:37] [ X203.877 Y-182.248 Z57.338 ] ok

    [17:51:37] [ X204.056 Y-181.821 Z57.322 ] ok

    [17:51:37] [ X204.169 Y-181.373 Z57.306 ] ok

    [17:51:37] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:51:37] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ X204.214 Y-180.912 Z57.29 ]

    [17:51:37] [ X204.214 Y-180.912 Z57.29 ] ALARM:1

    [17:51:38] [ X204.214 Y-180.912 Z57.29 ] [MSG:Reset to continue]

    [17:51:38] [ X204.214 Y-180.912 Z57.29 ] ok

    [17:51:38] [ X204.191 Y-180.451 Z57.274 ] Grbl 1.1g ['$' for help]

    [17:51:38] [ X204.191 Y-180.451 Z57.274 ] [MSG:Check Limits]

    [17:51:38] [ X204.191 Y-180.451 Z57.274 ] [MSG:'$H'|'$X' to unlock]

    [17:51:38] [ ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]<hr>This error may just be a symptom of an earlier event:<br> ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.

    [17:51:38] [ ERROR ] error: 9 - G-code locked out during alarm or jog state [ X204.191 Y-180.451 Z57.274 ]

    This error may just be a symptom of an earlier event:
    ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended.
    [17:51:38] [ X204.191 Y-180.451 Z57.274 ] error:9

    [17:51:49] [ ] Grbl 1.1g ['$' for help]

    [17:51:49] [ ] [MSG:Check Limits]

    [17:51:49] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:49] [ ] [MSG:Caution: Unlocked]

    [17:51:49] [ JOB COMPLETE ] Job completed in 00h00m

    [17:51:49] [ ] ok

    [17:51:52] [ G53 G0 Z-5.000 ] ok

    [17:51:52] [ G0 X0 Y0 ] ok

    [17:51:52] [ G0 Z0 ] ok

    [17:51:52] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:51:53] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [17:51:53] [ ] ALARM:1

    [17:51:53] [ ] [MSG:Reset to continue]

    [17:51:53] [ ] Grbl 1.1g ['$' for help]

    [17:51:53] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:54] [ ] Grbl 1.1g ['$' for help]

    [17:51:54] [ ] [MSG:'$H'|'$X' to unlock]

    [17:51:55] [ ] [MSG:Caution: Unlocked]

    [17:51:55] [ ] ok

    [17:51:57] [ G53 G0 Z-5.000 ] ok

    [17:51:57] [ G0 X0 Y0 ] ok

    [17:51:57] [ G0 Z0 ] ok

    [18:04:11] [ ] Grbl 1.1g ['$' for help]

    [18:06:19] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [18:06:19] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [18:06:19] [ ] ALARM:1

    [18:06:20] [ ] [MSG:Reset to continue]

    [18:06:20] [ ] Grbl 1.1g ['$' for help]

    [18:06:20] [ ] [MSG:'$H'|'$X' to unlock]

    [18:06:23] [ ] Grbl 1.1g ['$' for help]

    [18:06:23] [ ] [MSG:'$H'|'$X' to unlock]

    [18:06:23] [ ] [MSG:Caution: Unlocked]

    [18:06:23] [ ] ok

    [18:07:08] [ ] Grbl 1.1g ['$' for help]

    [18:07:08] [ ] ok

    [18:07:11] [ ALARM ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [18:07:11] [ ] ALARM: 1 - Hard limit triggered. Machine position is likely lost due to sudden and immediate halt. Re-homing is highly recommended. [ undefined ]

    [18:07:11] [ ] ALARM:1

    [18:07:12] [ ] [MSG:Reset to continue]

    [18:07:12] [ ] Grbl 1.1g ['$' for help]

    [18:07:12] [ ] [MSG:'$H'|'$X' to unlock]

    [18:08:18] [ ] Grbl 1.1g ['$' for help]

    [18:08:18] [ ] [MSG:'$H'|'$X' to unlock]

    [18:08:18] [ ] [MSG:Caution: Unlocked]

    [18:08:18] [ ] ok
     
  10. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    13,753
    Likes Received:
    4,070
  11. JustinTime

    JustinTime Veteran
    Builder

    Joined:
    Dec 18, 2013
    Messages:
    756
    Likes Received:
    252
    @Fintan Mitchell.
    1. You don't past a long file, that way people don't have to scroll all the way to the bottom. You post it in an attached file. Just Netiquette. :D
    2. I had the same problem with the end switch triggering and I cured it by putting a 0.01 micro farad tiny capacitor between the end switch on the pin of the Arduino and the ground. I did this for all three axes.
     