Welcome to Our Community

Some features disabled for guests. Register Today.

No power to BlackBox32

Discussion in 'General Talk' started by jltcet, Oct 4, 2024.

  1. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    I just finished rebuilding the machine and when I go to power it on the Blackbox has no power to it. I’ve tested the wiring to the box it’s got power, also it zapped me one time while testing ⚡️only thing I can think of is there a limit as to how long the cord from the power to the Blackbox can be? I had to run a fairly long cord due to mounting issues. Any trouble shooting help would be greatly appreciated.

    thanks in advance
    Jerry
     
  2. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Also I’ve noticed when I power it on the little green LED on the power supply comes on, and when I plug it into the BB it goes off.
     
  3. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Update. Ive found what looks like a bad power supply end. (SEE PICS) Ive contacted Openbuild about it Its still under warranty but just only Nov 21 2023 I bought it Not sure if it will be covered or not. Power plug will not connect anymore, and looks like it might have melted just a smig or even broke. I doubled checked the wiring it was all correct so IDK what happened
     

    Attached Files:

  4. Gary Caruso

    Gary Caruso OpenBuilds Volunteer
    Staff Member Moderator Builder

    Joined:
    May 19, 2016
    Messages:
    1,193
    Likes Received:
    532
    You got zapped by 24v? better test the output of your power supply!
    Gary
     
  5. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    that’s just it nothing has changed sense I re-wired the motors, non of the settings were touched it wasn’t a bad shock just one of those O well alrighty moments
     
  6. Gary Caruso

    Gary Caruso OpenBuilds Volunteer
    Staff Member Moderator Builder

    Joined:
    May 19, 2016
    Messages:
    1,193
    Likes Received:
    532
    You can't feel 24v with dry skin, so check the output with a meter, the psu might be passing high voltage.
    Gary
     
    Peter Van Der Walt likes this.
  7. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    The melted pin tip on the connector, the symptoms etc points at likely a reverse polarity wiring (or upstream short) - quite possible a mistake while making up the new power cable.

    The zap sound/burn mark suggests the reverse polarity cable / or some upstream shorts was plugged in while PSU was on as well

    Sorry to hear about this.

    Apply reverse polarity likely took out the BlackBox
     
  8. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    I don’t get why it happened though. I even tried the original cable and the black box still wouldn’t turn on. This was before the short when the plug would still insert into the black box. The short happed after I reinstalled the new cable. I was trying to see if the shorter power cable would power on the Blackbox. But it didnt. So something was going on before the short happened. I can’t afford to have this happen again if they can even fix it. It’s not like they’re cheap if I end up having to purchase a new one just to have it short out also. I guess I run a whole new power cable. Can you put an inline fuse to hopefully catch an issue like this if it happens again.
    Thanks felling really bummed right now. I’m sure this mistake is gonna be costly
     
  9. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    Post pics of both ends of the new cable, lets help check polarity?

    If its not that happy to check any other wiring/mounting pics for you too so we can help see what the root cause was.

    Fuses are not fast enough - checking polarity and wiring before powering on is more important.

    Feels all the more like new cable was wired incorrectly - damage already done, thats why old cable doesn't make a difference
     
  10. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    ok I’ll post some pics tomorrow of the cable I’m gonna replace it anyway. So no fuse huh? Dame feeling gun shy right about now. ok thanks Peter.
     
    Peter Van Der Walt likes this.
  11. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    So this is how I have it set up for the power wire. As you can see black box is off the machine but I’ve showed where it’s located, the psu mounting location the power wire runs under the machine up the front through the drag chain
     

    Attached Files:

  12. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    is this the correct ohms setting for testing
     

    Attached Files:

  13. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Also in order new wire for the power 12g should suffice correct?
     
  14. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    So I tested the polarity here’s a link
    IMG_1714.MOV

    Sorry didn’t mean ohms ment polarity
     
  15. Gary Caruso

    Gary Caruso OpenBuilds Volunteer
    Staff Member Moderator Builder

    Joined:
    May 19, 2016
    Messages:
    1,193
    Likes Received:
    532
    For the 24v side you would want DCV, can't see in the video where you were measuring 46V AC?
     
  16. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    That cat the end of the cord where it would hook into the Blackbox plug
     
  17. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
  18. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    Incorrect polarity wouldn't necessarily "go negative" as long as you hold the probes right (PSU side wiring correct, probes correct, measurement all good)

    But if the GND was wired to V+ and V+ to GND (can no longer check it because free end of cable already removed from how it was) it would 100% match the symptoms :(
    Just from the symptoms I have almost no doubt that is the history. Just lines up: was rewiring, easy to make that mistake in a moment of distraction. Afterwards symptoms match exactly what we see from folks where confirmed to be the case (wiring pics still will mistake in situ, etc)
     
  19. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23

    I guess its possible I did that, to tell the truth I must have taken it apart a dozen time looking, checking on the power side of the box. Do you think its fixable?
     
  20. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    Sadly not. In a soft start, it survives, but that sparking marks are indicative that power was on at the time of connection, blew up crowbar diode and usually makes its way deeper in burning stepper drivers, stepdown converter, spindle control etc all the sections on the 24v rail. Often jumps the burnt stepdown too and pumps reverse polarity 24v into the low voltage rails taking out microcontroller etc too. Labour on microsoldering is expensive, and with the amount of power involved burnt pcb traces almost certain too. So will probably cost 2-3x the cost of a new one to get it repaired
     
  21. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23

    DAME that sucks Ok well IMHOP I think Openbuild should find a way to build in a protector into the system,I mean it would make sense to protect a valuable pice of equipment. But thats just my thoughts. SOooooo is OB going to want this thing back or should I just order a new one Just looking of a answer I mean I know they can't fix it so I have to order a new one I get that Very frustrated right now that theres no built in protection for this very expensive item :mad:
     
  22. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Ok ordered a new box :brb::brb::brb::brb::brb::brb::brb::brb: this time Im going to insure the box, and the controler.
     
  23. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    There is, but connecting to a PSU while the PSU is powered on means instead of a nice soft start from the PSU (sees reverse blocking diode, PSU goes into protection mode as engineered), it got hit with the full charge of the already on PSU (causing the burn marks on the connectors) - two mistakes (working with power on and reverse polarity at the same time) took its toll here. I am sorry it happened to you, but please always work with everything powered OFF and always double check wiring before powering on.
     
  24. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Thanks for the help. I know it was powered off before I connected the BB plug because I have a on off switch at the PSU. I cant rule out that I accidentally wired the + to the - I can tell you I spent all morning running new wires to every thing and by the time I got to the power it was 109* out side probably a little less in my garage, and like you said distracted HOT didn't help :sleepy: But either way Ive ordered a new BB should be here shortly and tired didn't help
    Thanks again
     
  25. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Say Peter.
    I’ve got the new black box hooked up and running but now I can’t hook it to the computer. Interface works but I’m guessing sense it’s a windows 7 pro it will no longer recognize it (thought I heard somewhere) any way how to I load my back up settings into the black box with out the computer I have it on a usb but unsure how to load it from the interface or if it’s even possible

    thanks again
    Jerry
     
  26. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    Newer versions of CONTROL needs Windows 10 yes

    But in terms of "recognising" as in USB Enumaration, make sure you have the drivers docs:blackbox-x32:install-drivers [OpenBuilds Documentation] - newer BlackBoxes has a different USB chip (Silicon labs, no longer FTDI)
     
  27. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    ok thank you on it I’ll let ya know thanks
     
    Peter Van Der Walt likes this.
  28. jltcet

    jltcet Well-Known
    Builder

    Joined:
    Oct 24, 2023
    Messages:
    148
    Likes Received:
    23
    Setting are in everything looks good tested the Openbuilds limit switches all working Home the machine. Everything is looking great. Going to go over it with a good eye before starting on a price had on hold for 3 weeks.

    thank you all for your input
    Thanks Peter again for getting me up and running
     
    Peter Van Der Walt likes this.
  29. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,866
    Likes Received:
    4,283
    Awesome stuff, great to have you back in action.
     
    jltcet likes this.

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice