Welcome to Our Community

Some features disabled for guests. Register Today.

Disable Z axis homing

Discussion in 'Controller Boards' started by gmhudson, Aug 21, 2023.

  1. gmhudson

    gmhudson New
    Builder

    Joined:
    Jun 24, 2023
    Messages:
    12
    Likes Received:
    0
    Is there an easy way to disable Z axis homing (at the same time as maintaining Y2 ganged to X axis)?

    Or to disable Z axis entirely (I have none, but if the Z axis buttons are pressed it wakes up the X and Z steppers …).

    thanks
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,870
    Likes Received:
    4,283
    Which controller do you have?
     
  3. gmhudson

    gmhudson New
    Builder

    Joined:
    Jun 24, 2023
    Messages:
    12
    Likes Received:
    0
    X32
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,870
    Likes Received:
    4,283
    On the X32, running grblHAL, you can
    Set $44=1 to home X first
    Set $45=2 to home Y after

    or

    Set $44=3 to home XY at the same time and
    Set $45=0 (currently has value, clear it with a zero)

    Additional or extended settings

    Setting $1=255 is advisable to keep motors always on - Step Idle turning the motors off can cause loss of position Grbl v1.1 Configuration
     
  5. gmhudson

    gmhudson New
    Builder

    Joined:
    Jun 24, 2023
    Messages:
    12
    Likes Received:
    0
     
  6. gmhudson

    gmhudson New
    Builder

    Joined:
    Jun 24, 2023
    Messages:
    12
    Likes Received:
    0
    Ok thanks, works.

    I’m turning the steppers off to avoid any possibility of burning out motors or board at the moment … it is worrisome hearing them humming when stationary …

    The context sensitivity / mouse over help for the settings seems to be intermittent btw (I get no help for these settings at the moment, for example).

    thanks
     
  7. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,870
    Likes Received:
    4,283
    For that to happen the motors would have to be electrically incorrectly spec'ed, or driver current set too high. Its designed to be always on
     
  8. David the swarfer

    David the swarfer OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Aug 6, 2013
    Messages:
    3,430
    Likes Received:
    1,907
    so long as you can hold a finger on a hot motor for 5 seconds they are not too hot
     