Welcome to Our Community

Some features disabled for guests. Register Today.

error 9

Discussion in 'General Talk' started by jean pierre husquinet, Dec 5, 2021.

  1. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
    Hello to all! Can somebody help? I have constantly this message coming up: Error 9- G-code locked or jog state (G1X92.8757Y181.9428). For the same job, sometimes it will complete but mainly stops here and there with this message???
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,765
    Likes Received:
    4,266
    The alarm would have shown more info, particularly the ALARM that caused the lock
    Rather screenshot, or note down complete messages so we can help you locate the root cause
     
  3. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
     

    Attached Files:

  4. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
    Thank you Peter, here is the screenshot
     
  5. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,765
    Likes Received:
    4,266
    Right, so it was an alarm, caused by a limit switch that triggered.

    Did it hit a switch at the time? If not, that would be a False Hard Limit - most likely caused by Electromagnetic Interference. See docs:blackbox:faq-emi [OpenBuilds Documentation]
     
  6. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
    Reading the other members questions and answers, It's probably the case, so I will check that. To answer your question, It did not touch any switch limit. Many thanks for the advice, Let's check and hope!
    Cheers
    jp
     
  7. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
    Hello Peter, I promised to keep you informed, so after checking and putting everything to earth, some progress as been made, the machine worked for 2h30 hours then I got another error message (see file attached) Anyway thanks again for your help!
    Cheers
    jp
     

    Attached Files:

  8. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,765
    Likes Received:
    4,266
    at xx:58:10 in the log you can see your controller rebooted (or at least appears to have)

    Either
    • EMI based USB reset,
    • some other application on your computer that scanned USB/Serial ports and thus triggered a reset,
    • someone hit the reset button on the front of the BlackBox,
    • or you have a wiring short somewhere that briefly shorted V+ to GND starving the controller of its 5v rail, causing a brown-out reset.

    Could also be computer related:
     
  9. jean pierre husquinet

    Builder

    Joined:
    Nov 23, 2020
    Messages:
    6
    Likes Received:
    1
    I am actually searching for another computer as the one I am working with is very old. That might be a problem I guess. I'll make some changes soon as I can.
    Thanks and all the best
     
    Peter Van Der Walt likes this.

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice